A registered trademark from the Canada

Sale!

Combination Smoke and Carbon Monoxide Detector Alarm, Beeps Warning Smoke Co Alarm Clock for Travel Home Bedroom Living Room Garage Basement Attics, Battery Operated, Comply With UL 217 and UL 2034, 1 Pack

Original price was: $60.46.Current price is: $50.38.

  • ???est this alarm First, HOW TO TEST IT(3 steps): 1. Install the batteries in clean air, then press the test button for five seconds to test the unit electronics, beeps will sound if it’s normal; 2. Leave it in clean air for one minute; 3. put it into a sealed bag, spray some smoke or CO gas into the bag and seal it. Waiting for about one minute, the Alarm will go off if it’s normal. NOTE: DO NOT test it by directly burning something under this alarm, which is an invalid test.
  • ???eep your family safe with this battery operated smoke and carbon monoxide alarm; battery powered alarms provide continuous monitoring of CO and smoke levels, even if there’s a power failure. Features an electrochemical sensing technology and a photoelectric sensor that detects the larger particles of a smoldering fire. Please thoroughly read PRODUCT DESCRIPTION and the user manual before using.
  • ???ndicator lights on the face of the unit display the presence of smoke and carbon monoxide, while an 85dB beeps siren provides a clear, loud warning upon detection
  • ???2 * AA Battery-operated unit installs quickly and easily without an electrician, Can connect to other compatible detectors, To ensure all alarms will sound when threat is detected(Battery not included)
  • ???imensions: 4 * 4 * 1.5 inch. Simple to use, NOTE: When installation please follow the circular arrow direction that Marked on the product for rotating the Mounting base/Bracket: PRESS DOWN AND TWIST; Do not install it in kitchens/garages/furnace room/bathrooms. A single button tests the unit or silences the alarm. Low battery signal mute, quiets low battery signal for up to 8 hours. if there is any problems, please feel free to contact us, we are always here to help you.
  • Combination Smoke Detector Alarm and Carbon Monoxide Detector Alarm Can Detect the threat of these Two Gases: Smoke and Carbon Monoxide. KEEP YOU FAMILY SAFE THEN EVER

  1. Photoelectric Sensor Detects Smoke, Smoke Detect While Minimizing the false alarms.
  2. Carbon Monoxide Detector alarm Using High accurate Electrochemical Sensor, alerts you to Carbon Monoxide Danger. insurance Safety of your life.
  3. Suitable for all the Place Possible to Produce Cambo Smoke and Carbon Monoxide, Such as your Home, Living room, Bedroom, Dinning room, Hotel, Cars… Also Useful When you are Enjoying the Barbecue, Using Charcoal Warm yourself, or Putting it in your Parking Garage, etc.

  • NOTE:

  1. Please thoroughly read the user manual before using.
  2. If the unit sounds all the time or it is of malfunction, please reinstall the battery to repeat the operation until it’s normal.

  • Test the alarm First, HOW TO TEST IT(3 steps):

  1. Step 1: Install the batteries in clean air , then press the test button for five seconds to test the units electronics, beeps will sound if it’s normal;
  2. Step 2: Leave it in clean air for one minute;
  3. Step 3: Then put it into a sealed bag, spray some smoke or CO gas into the bag and seal it. Waiting for about one minute, the Alarm will go off if it’s normal.

[NOTE: DO NOT test it by directly burning something under this alarm, which is an invalid test.]

  • HOW TO SILENCE THE ALARM

  1. SMOKE ALARM BEEPS: When smoke alarm beeps you can press the test/rest button to enter it into mute state(NOTE: If you want to exit the mute state, you need to press the button again-[Manually exit]; or it will auto-exit the mute state after waiting for about 6 munites or when the alarm detected clean air-[Auto-exit])
  2. CO ALARM BEEPS???nly when detected clear air can it silence the alarm(if the room still exists high level of CO the alarm will keep alarming until the air was cleaned)
co smoke detector

  • Working Parameter

  1. Sensitivity & Time for CO Alarm: [50ppm, alarming within 90 minutes] / [100ppm, alarming within 40 minutes] / [300ppm, alarming within 3 minutes]
  2. Sensitivity for Smoke Alarm: 0.1~1.0dB/m
  3. Standby Current: <80uA
  4. Alarm Current: <80mA
  5. Operation Ambient Condition: 5~400C, 20~90%R.H

  • Easy to install

  1. Turn the alarm body counterclockwise and take off the bracket.(When installation please follow the circular arrow direction that Marked on the product for rotating the Mounting base/Bracket: PRESS DOWN AND TWIST)
  2. Hold the bracket in the installation position as specified in the Recommended Locations, mark installation holes of the bracket with pencil.
  3. Drill the two marked installation holes; Tap the two plastic grommets into holes with hammer.
  4. Mount the bracket to the ceiling by inserting and tightening the supplied screws into plastic grommets. Fix the alarm on the bracket and turn the alarm body clockwise, until fully inserted on the bracket. Do not install it in kitchens/garages/furnace room/bathrooms, INSTALL AT LEAST 15 FEET AWAY FROM ANY FUEL BURNING APPLIANCE.

  • Appearance and Button

  1. Green LED: The green LED flashes every 40 seconds to indicate the unit operate properly
  2. Red LED: When a dangerous level of smoke or carbon monoxide is detected the red LED will continuously flash and the alarm will sound: The alarm sound pattern is four short alarm beeps for CO alarm and continuous beeps for the smoke alarm.
  3. One ?M??hirp?M?every 40 seconds is an indication that the battery is low

Reviews

There are no reviews yet.

Be the first to review “Combination Smoke and Carbon Monoxide Detector Alarm, Beeps Warning Smoke Co Alarm Clock for Travel Home Bedroom Living Room Garage Basement Attics, Battery Operated, Comply With UL 217 and UL 2034, 1 Pack”
SKU: QV9R24Q70B Category: